LayerZero Technologies

LayerZero Power Systems engineering applies impeccable attention to detail, taking novel and groundbreaking approaches towards routine problems that are experienced in the data center.

LayerZero sets its own standards, thinking in a "Mode of Reliability". Uptime is the reason behind all of our design features.

Most of these technology advancements were developed years before similar systems, and they include a variety of features that are exclusive to LayerZero.

The technologies inside LayerZero systems are designed to maximize system reliability, increase operator safety, and enable connectivity within the equipment.

Epoxy Coated Buswork

Epoxy Coated Buswork

Many of our electrical components include a durable protective epoxy coating. The use of epoxy coated buswork allows us to maximize efficiency, precision, help ensure safety, and be highly resistant to corrosion.

Epoxy Coated Buswork
Inrush Mitigation

Inrush Mitigation

Our exclusive Dynamic Phase Compensation technology helps protect upstream sources and downstream critical loads from transformer inrush currents by constantly monitoring the power and introducing an appropriate delay during switching. This delay significantly reduces inrush currents for out-of-phase transfers, preventing upstream tripping, and eliminating potential UPS overload.

Inrush Mitigation
Low Maintenance Technologies

Low Maintenance Design

LayerZero systems are designed to reduce maintenance demands and increase reliability. Through passive convection cooling, precision-machined hardware, and brazed maintenance-free joints, our power distribution systems are engineered to eliminate common failure points—resulting in greater uptime and lower operational costs.

Low Maintenance Design
Open Communication

Non-Proprietary Connectivity

We offer a variety of connectivity options to an array of open protocols, which empowers operators to collect information such as metering, alarms, waveforms, setpoints, event logs, panel setup, and diagnostics. Supported protocols include:
• Modbus
• https://
• SNMP
• Dry Contacts

Connectivity
Protecting Upstream Devices

Selective Trip Coordination

Selective trip coordination in the most critical distribution segment of branch circuit protection. Selective Tripping means that when a fault occurs anywhere in the distribution system, one and only one breaker will trip. That breaker will always be located upstream and closest to the fault. LayerZero Power Systems products have been designed and tested for coordination, assuring that if a downstream fault occurs, upstream devices will be protected.

Selective Trip Coordination
Silver Plating

Silver Plating

LayerZero utilizes silver plating on all of its copper bus connection points in order to provide the highest performance possible.

Silver has high conductivity and low resistance - which makes for a great contact surface.

Silver Plating
Stainless Steel Hardware

Stainless Steel Hardware

Zinc whiskers are filaments of zinc that grow on galvanized metal surfaces. Zinc whiskers are conductive and will cause short circuits if they bridge electrical conductors. Zinc whisker-induced short circuits have been cited as the direct cause of many catastrophic data center failures in recent years.

Stainless Steel Hardware
Touch-Screen Interface

Touch Screen Interface

All functions of our eSTS and ePODs units are controlled through a 15" color touch screen LCD mounted to the front of the unit. The touch-screen features power flow diagrams, step-by-step instructions, waveforms, metering, and all alarm information. In the unlikely instance of a failure of the display module, our eSTS and ePODs will maintain full switching and distribution functionality.

Touch Screen Interface